代码讲解Python对Windows服务进行监控

yipeiwu_com6年前Python基础

我们首先来看下python的全部代码,大家可以直接复制后测试:

#-*- encoding: utf-8 -*-  
import logging  
import wmi  
import os  
import time  
from ConfigParser import ConfigParser  
import smtplib  
from email.mime.text import MIMEText  
import socket 
from datetime import datetime 
import re 
import sys 
import time 
import string 
import psutil  
import threading 
from threading import Timer   
import logging 
# 创建一个logger  
logger = logging.getLogger('Monitor')  
logger.setLevel(logging.DEBUG)  
   
# 创建一个handler,用于写入日志文件  
fh = logging.FileHandler('test.log')  
fh.setLevel(logging.DEBUG)  
   
formatter = logging.Formatter('%(asctime)s - %(name)s - %(levelname)s - %(message)s')  
fh.setFormatter(formatter)  
logger.addHandler(fh)  

reload(sys) # Python2.5 初始化后会删除 sys.setdefaultencoding 这个方法,我们需要重新载入  
sys.setdefaultencoding('utf-8')  
 
def send_mail(to_list,sub,content):  
  CONFIGFILE = 'config.ini'  
  config = ConfigParser()  
  config.read(CONFIGFILE)  
  mail_host=config.get('Mail','mail_host')      #使用的邮箱的smtp服务器地址,这里是163的smtp地址  
  mail_user=config.get('Mail','mail_user')              #用户名  
  mail_pass=config.get('Mail','mail_pass')                #密码  
  mail_postfix=config.get('Mail','mail_postfix')           #邮箱的后缀,网易就是163.com  
  me=sub+"<"+mail_user+"@"+mail_postfix+">"  
  msg = MIMEText(content,_subtype='plain',_charset='utf-8')  
  msg['Subject'] = sub  
  msg['From'] = me  
  msg['To'] = ";".join(to_list)        #将收件人列表以‘;'分隔  
  try:  
    server = smtplib.SMTP()  
    server.connect(mail_host)              #连接服务器  
    server.login(mail_user,mail_pass)        #登录操作  
    server.sendmail(me, to_list, msg.as_string())  
    server.close()  
    return True  
  except Exception, e:  
    print str(e) 
    logger.info(str(e))    
    return False  
 
 
 #读取配置文件中的进程名和系统路径,这2个参数都可以在配置文件中修改 
ProList = []  
#定义一个列表 
c = wmi.WMI()  
 
#获取进程所用内存 
def countProcessMemoey(processName): 
  try: 
    CONFIGFILE = 'config.ini'  
    config = ConfigParser()  
    config.read(CONFIGFILE)  
 
    pattern = re.compile(r'([^\s]+)\s+(\d+)\s.*\s([^\s]+\sK)') 
    cmd = 'tasklist /fi "imagename eq ' + processName + '"' + ' | findstr.exe ' + processName 
    result = os.popen(cmd).read() 
    resultList = result.split("\n") 
    totalMem = 0.0 
    totalCpu = 0.0 
 
    print "*" * 80 
    for srcLine in resultList: 
      srcLine = "".join(srcLine.split('\n')) 
      if len(srcLine) == 0: 
        break 
      m = pattern.search(srcLine) 
      if m == None: 
        continue 
      #由于是查看python进程所占内存,因此通过pid将本程序过滤掉 
      if str(os.getpid()) == m.group(2): 
        continue 
      p = psutil.Process(int(m.group(2))) 
      cpu = p.cpu_percent(interval=1)   
      ori_mem = m.group(3).replace(',','') 
      ori_mem = ori_mem.replace(' K','') 
      ori_mem = ori_mem.replace(r'\sK','') 
      memEach = string.atoi(ori_mem) 
      totalMem += (memEach * 1.0 /1024) 
      totalCpu += cpu 
      print 'ProcessName:'+ m.group(1) + '\tPID:' + m.group(2) + '\tmemory size:%.2f'% (memEach * 1.0 /1024), 'M' + ' CPU:'+str(cpu)+'%' 
    print 'ProcessName:'+ m.group(1)+' TotalMemory:'+str(totalMem)+'M'+' totalCPU:'+str(totalCpu)+'%' 
    logger.info('ProcessName:'+ m.group(1)+' TotalMemory:'+str(totalMem)+'M'+' totalCPU:'+str(totalCpu)+'%') 
    print "*" * 80 
      
    if totalMem> float(config.get('MonitorProcessValue','Memory')): 
      print 'Memory Exceed!' 
      IP = socket.gethostbyname(socket.gethostname()) 
      now = datetime.now().strftime('%Y-%m-%d %H:%M:%S') 
      subject = IP +' ' + processName + '内存使用量过高!' 
      content = now + ' ' + IP +' ' + processName + '内存使用量过高,达到'+str(totalMem) +'M\n请尽快处理!' 
      logger.info(processName +'内存使用量过高,达到'+str(totalMem) +'M') 
      send_mail(['sunwei_work@163.com','sunweiworkplace@gmail.com'],subject, content) 
    if totalCpu > float(config.get('MonitorProcessValue','CPU')): 
      print 'CPU Exceed!' 
      IP = socket.gethostbyname(socket.gethostname()) 
      now = datetime.now().strftime('%Y-%m-%d %H:%M:%S') 
      subject = IP +' ' + processName + 'CPU使用率过高!' 
      content = now + ' ' + IP +' ' + processName + 'CPU使用率过高,达到'+str(totalCpu)+'%\n请尽快处理!' 
      logger.info(processName +'CPU使用率过高,达到'+str(totalMem) +'M') 
      send_mail(['sunwei_work@163.com','sunweiworkplace@gmail.com'],subject, content) 
  except Exception, e:  
    print str(e) 
    logger.info(str(e))   
  
#判断进程是否存活 
def judgeIfAlive(ProgramPath,ProcessName): 
  try: 
    print datetime.now().strftime('%Y-%m-%d %H:%M:%S') 
    for process in c.Win32_Process():  
      ProList.append(str(process.Name))  
    #把所有任务管理器中的进程名添加到列表 
 
    if ProcessName in ProList: 
      countProcessMemoey(ProcessName)  
    #判断进程名是否在列表中,如果是True,则所监控的服务正在 运行状态, 
    #打印服务正常运行 
      print ''  
      print ProcessName+" Server is running..."  
      print ''  
      logger.info(ProcessName+" Server is running...") 
    else:  
      #如果进程名不在列表中,即监控的服务挂了,则在log文件下记录日志 
      #日志文件名是以年月日为文件名 
      IP = socket.gethostbyname(socket.gethostname()) 
      now = datetime.now().strftime('%Y-%m-%d %H:%M:%S') 
      subject = IP +' ' + ProcessName + '已停止运行!' 
      logger.info( ProcessName + '已停止运行!') 
      content = now + ' ' + IP +' ' + ProcessName + '已停止运行!' +'\n请尽快处理!' 
      send_mail(['sunwei_work@163.com','sunweiworkplace@gmail.com'],subject, content) 
      print ProcessName+' Server is not running...'  
      #打印服务状态 
      logger.info('\n'+'Server is not running,Begining to Restart Server...'+'\n'+(time.strftime('%Y-%m-%d %H:%M:%S --%A--%c', time.localtime()) +'\n')) 
      #写入时间和服务状态到日志文件中 
      os.startfile(ProgramPath)  
      #调用服务重启 
      logger.info(ProcessName+'Restart Server Success...'+'\n'+time.strftime('%Y-%m-%d %H:%M:%S --%A--%c', time.localtime())) 
      print ProcessName+'Restart Server Success...'  
      print time.strftime('%Y-%m-%d %H:%M:%S --%A--%c', time.localtime())  
    del ProList[:]  
    #清空列表,否则列表会不停的添加进程名,会占用系统资源 
  except Exception, e:  
    print str(e) 
    logger.info(str(e))   
def startMonitor(ProgramPathDict,ProcessNameDict) :  
  for i in range(0,len(ProcessNameDict)): 
    judgeIfAlive(ProgramPathDict[i],ProcessNameDict[i]) 
if __name__=="__main__" :  
  CONFIGFILE = 'config.ini'  
  config = ConfigParser()  
  config.read(CONFIGFILE)  
  ProgramPathDict = config.get('MonitorProgramPath','ProgramPath').split("|")  
  ProcessNameDict = config.get('MonitorProcessName','ProcessName').split("|") 
  while True:  
    startMonitor(ProgramPathDict,ProcessNameDict)  
    time.sleep(int(config.get('MonitorProcessValue','Time'))) 

所用配置文件config.ini

[MonitorProgramPath]  
ProgramPath: C:\Windows\System32\services.exe|C:\Program Files (x86)\Google\Chrome\Application\chrome.exe  
[MonitorProcessName]  
ProcessName: services.exe|chrome.exe 
[MonitorProcessValue] 
Memory:5000.0 
CPU:50.0 
Time:60 
[Mail]  
mail_host: smtp.163.com 
mail_user:  
mail_pass:  
mail_postfix: 163.com 

以上就是本次小编整理的关于Python对Windows服务进行监控的全部代码内容,感谢你对【听图阁-专注于Python设计】的支持。

相关文章

详解多线程Django程序耗尽数据库连接的问题

Django的ORM是非常好用的,哪怕不是做Web项目也值得一用,所以网上也可以找到不少使用 Django 开发非Web项目的资料,因为除了ORM之个,命令行、配置文件等组件也非常好用。...

Python装饰器用法实例总结

本文实例讲述了Python装饰器用法。分享给大家供大家参考,具体如下: 一、装饰器是什么 python的装饰器本质上是一个Python函数,它可以让其他函数在不需要做任何代码变动的前提下...

python实现单向链表详解

python实现单向链表详解

本文研究的主要是Python中实现单向链表的相关内容,具体如下。 什么是链表 链表顾名思义就是~链 链表是一种动态数据结构,他的特点是用一组任意的存储单元存放数据元素。链表中每一个元...

实例分析python3实现并发访问水平切分表

场景说明 假设有一个mysql表被水平切分,分散到多个host中,每个host拥有n个切分表。 如果需要并发去访问这些表,快速得到查询结果, 应该怎么做呢? 这里提供一种方案,...

Python判断变量名是否合法的方法示例

Python判断变量名是否合法的方法示例

问题: 变量名是否合法:          1.变量名可以由字母,数字或者下划线组成   &nb...